TD2167
Power Transformer
This page provides complete and verified information for part number TD2167, NSN 5950-01-199-9078
You’ll find detailed technical specifications, product attributes, condition classification, and real-time stock availability. All data is based on official records and meets industry standards for defense, aerospace, and industrial sourcing. Whether you’re performing a parts audit, validating compliance, or preparing a purchase order, this part listing supports accurate and efficient procurement.
An enclosure of other than cast metal designed to house, mount, and protect, but does not include wiring connections or electrical device(s) such as terminals and/or terminal boards, switches, jacks, fuseholders, connectors, circuit breakers and the like. It is designed for and may include a cover and such accessories as mounting hardware, brackets, locks, clamps, mounts and conduit fittings. Excludes:conduit outlet; and chamber, cable terminal. For boxes which include electrical device(s) such as terminals and/or terminal boards, switches, fuseholders, jacks, connectors, circuit breakers and the like, or combinations thereof, see switch box; fuze box; jack box; terminal box; circuit breaker box; and distribution box. For boxes wired to provide the interconnecting facilities for a specific major group of electronic items outside of the box, see interconnecting box. See also interconnecting cabinet. __________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
single phase to single phase single component input-output phase relationship, 3.720 inches minimum and 3.780 inches maximum single mounting facility single center group center to center distance between mounting facilities parallel to length, not established reliability indicator, 2.470 inches minimum and 2.530 inches maximum single mounting facility single center group center to center distance between mounting facilities parallel to width, 60.0 hertz nominal single component frequency rating
Characteristics
Below are the official specifications and performance details for this part, including technical data, material composition, and compliance information.
- Reliability Indicator
- not established
- Center To Center Distance Between Mounting Facilities Parallel To Length
- 3.720 inches minimum and 3.780 inches maximum single mounting facility single center group
- Center To Center Distance Between Mounting Facilities Parallel To Width
- 2.470 inches minimum and 2.530 inches maximum single mounting facility single center group
- Frequency Rating
- 60.0 hertz nominal single component
- Input-Output Phase Relationship
- single phase to single phase single component
- Winding Shielding Method
- grounded to inclosure, core and mounting single component
- Body Length
- 4.690 inches maximum
- Body Outside Diameter
- 4.000 inches maximum
- Body Width
- 3.500 inches maximum
- Maximum Operating Temp
- 71.0 celsius
- Inclosure Type
- fully inclosed
- Mounting Facility Quantity
- 4 single group
- Mounting Method
- threaded hole single group
- Winding Function And Quantity
- 1 primary and 3 secondary single component
- Nominal Thread Size
- 0.190 inches single group
- Winding Operating Current
- 1.3 amperes ac nominal single component 1st secondary
- Winding Operating Current
- 2.0 amperes ac nominal single component 2nd secondary
- Winding Operating Current
- 2.6 amperes ac nominal single component 3rd secondary
- Winding Operating Voltage
- 16.30 ac volts nominal single component 2nd secondary
- Winding Operating Voltage
- 115.00 ac volts nominal single component single primary
- Winding Operating Voltage
- 39.60 ac volts nominal single component 1st secondary
- Winding Operating Voltage
- 43.00 ac volts nominal single component 3rd secondary
- Thread Series Designator
- unf single group
- Terminal Type And Quantity
- 13 eyelet
Classification Data
Detailed NSN information including identification codes, classification data, and key indicators used for cataloging, logistics, and supply management.
- Type of Item Identification
- Demilitarization
- Criticality
- Federal Item Identification Guide
- Precious Metals Indicator
- Pseudo Item Name Code
- Hazardous Material Indicator
- 1 - Full descriptive item identification
- A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
- X - The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
- A058B0
- A - Item does not contain precious metal.
- 0032496
- P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Freight Information
Comprehensive freight classifications, shipping codes, and handling specifications for domestic and international transport compliance.
- Major Organizational Entity
- National Motor Freight Classification Item Number
- National Motor Freight Classification Sub-Item Number
- Uniform Freight Classification Item Number
- National Motor Freight Class Rating
- Water Commodity
- Type of Cargo
- Special Hand
- Air Dimension
- Air Commodity
- National Motor Freight Description
- TX
- 063420
- Z
- 35355
- W - Rating variable
- 595 - Transformer, (machinery and parts),(less than 35 feet)
- Z - No special type of cargo code applicable
- 9 - Other or no special handling required (sh)
- A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
- HZ -
- transformers,noi,or transformer par
FAQs
Get insights on installation procedures, operating conditions, care instructions, industry regulations, and common issues. FAQs below provide key information for TD2167
What is the FSCG of the NSN 5950-01-199-9078?
Does NSN 5950-01-199-9078 require demilitarization?
Does NSN 5950-01-199-9078 contain precious materials?
Does NSN 5950-01-199-9078 contain hazardous materials?
When the NSN 5950-01-199-9078 was assigned to the Federal Catalog?
Need Consumables?
Running low on essential supplies? Explore our extensive catalog of high-quality consumables designed to keep your operations on track.
Recommended for You
Discover a selection of other high-demand NSN components from our catalog. These featured parts are frequently sourced by procurement teams across defense, aerospace, and industrial sectors.
Price & Availability
Fill out the form to get accurate pricing, lead time, and stock details from our NSN specialists: