MK36064

Memory Microcircuit

This page provides complete and verified information for part number MK36064, NSN 5962-01-165-3107

You’ll find detailed technical specifications, product attributes, condition classification, and real-time stock availability. All data is based on official records and meets industry standards for defense, aerospace, and industrial sourcing. Whether you’re performing a parts audit, validating compliance, or preparing a purchase order, this part listing supports accurate and efficient procurement.

MK36064
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5962 Electronic Microcircuits
National Stock Number
5962-01-165-3107
Item Name Code
41015
Assigment Date
10/27/1983 (42 years ago)

+0.0 to 70.0 celsius operating temp range, 0.500 inches nominal body width, 1.0 watts maximum power dissipation rating, 1.250 inches nominal body length, 0.187 inches nominal body height

Characteristics

Below are the official specifications and performance details for this part, including technical data, material composition, and compliance information.

Body Length
1.250 inches nominal
Body Width
0.500 inches nominal
Body Height
0.187 inches nominal
Maximum Power Dissipation Rating
1.0 watts
Operating Temp Range
+0.0 to 70.0 celsius
Storage Temp Range
-65.0 to 150.0 celsius
End Item Identification
test set 9900a
Features Provided
hermetically sealed and w/enable and 3-state output and high performance
Inclosure Material
ceramic
Inclosure Configuration
dual-in-line
Output Logic Form
n-type metal oxide-semiconductor logic
Input Circuit Pattern
14 input
Terminal Surface Treatment
solder
Voltage Rating And Type Per Characteristic
7.0 volts maximum power source
Time Rating Per Chacteristic
250.00 nanoseconds maximum propagation delay time, low to high level output
Memory Device Type
rom
Memory Capacity
unknown
Terminal Type And Quantity
24 printed circuit

Classification Data

Detailed NSN information including identification codes, classification data, and key indicators used for cataloging, logistics, and supply management.

Type of Item Identification
1 - Full descriptive item identification
Automatic Data Processing Point
0 - Represents items with no adp components
Demilitarization
Q - "commerce control list items (ccli) - mut to the point of scrap required outside the united states. Inside the united states, mut is required when the demil integrity code (ic) is "3" and mut is not required when the demic is "6" (note 8)"
Criticality
X - The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Federal Item Identification Guide
A458A0
Precious Metals Indicator
A - Item does not contain precious metal.
Pseudo Item Name Code
0041015
Hazardous Material Indicator
N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Schedule B Code
8542900000

Freight Information

Comprehensive freight classifications, shipping codes, and handling specifications for domestic and international transport compliance.

Major Organizational Entity
TX
National Motor Freight Classification Item Number
061045
National Motor Freight Classification Sub-Item Number
Z
Uniform Freight Classification Item Number
34580
National Motor Freight Class Rating
W - Rating variable
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
Type of Cargo
3 - Electrostatic sensitive device (esd)
Special Hand
9 - Other or no special handling required (sh)
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Air Commodity
HZ -
National Motor Freight Description
boards printed circuit elec

FAQs

Get insights on installation procedures, operating conditions, care instructions, industry regulations, and common issues. FAQs below provide key information for MK36064

What is the FSCG of the NSN 5962-01-165-3107?
The FSCG of the NSN 5962-01-165-3107 is 5962
Does the NSN 5962-01-165-3107 have a Schedule B code assigned?
Yes, the Schedule B code is 8542900000
Does NSN 5962-01-165-3107 require demilitarization?
"commerce control list items (ccli) - mut to the point of scrap required outside the united states. Inside the united states, mut is required when the demil integrity code (ic) is "3" and mut is not required when the demic is "6" (note 8)"
Does NSN 5962-01-165-3107 contain precious materials?
Item does not contain precious metal.
Does NSN 5962-01-165-3107 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 5962-01-165-3107 was assigned to the Federal Catalog?
It was assigned 42 years ago, on Thu, Oct 27, 1983

Need Consumables?

Running low on essential supplies? Explore our extensive catalog of high-quality consumables designed to keep your operations on track.

Electrical Wires

Recommended for You

Discover a selection of other high-demand NSN components from our catalog. These featured parts are frequently sourced by procurement teams across defense, aerospace, and industrial sectors.

Price & Availability

Fill out the form to get accurate pricing, lead time, and stock details from our NSN specialists:

FREE

Aviation Suppliers Association Member AS9120-ISO9001 Certification

Popular Parts

Browse our top-performing parts, selected based on customer demand and procurement frequency. All listings include up-to-date specs, availability, and condition:

RW74U1650F
5905-00-945-5294
Resistor,fixed,wire Wound,induct
RW74U1651F
5905-00-887-9980
Resistor,fixed,wire Wound,induct
RW74U1690F
5905-01-163-3111
Resistor,fixed,wire Wound,induct
RW74U1691F
5905-00-948-2641
Resistor,fixed,wire Wound,induct
RW74U16R2F
5905-01-143-0997
Resistor,fixed,wire Wound,induct
RW74U1781F
5905-01-148-1154
Resistor,fixed,wire Wound,induct
RW74U17R8F
5905-01-232-2599
Resistor,fixed,wire Wound,induct
RW74U1800F
5905-01-177-4408
Resistor,fixed,wire Wound,induct
RW74U1801F
5905-01-097-5426
Resistor,fixed,wire Wound,induct
RW74U1822F
5905-00-827-5079
Resistor,fixed,wire Wound,induct
RW74U1872F
5905-00-688-9763
Resistor,fixed,wire Wound,induct
RW74U1911F
5905-01-237-6549
Resistor,fixed,wire Wound,induct
RW74U1912F
5905-01-073-8849
Resistor,fixed,wire Wound,induct
RW74U1960F
5905-01-085-5691
Resistor,fixed,wire Wound,induct
RW74U1962F
5905-00-236-2152
Resistor,fixed,wire Wound,induct