1. Home /
  2. Catalog /
  3. Switches /
  4. 5930-00-899-9023

5930-00-899-9023

Rotary Switch

Find complete technical information, availability, and procurement data for NSN 5930-00-899-9023 All details are based on official government and industry records to support accurate and compliant procurement.

5930-00-899-9023
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-00-899-9023
Item Name Code
02134
Assigment Date
02/03/1967 (59 years ago)

4.000 inches nominal overall length, explosion proof hazardous locations/environmental protection, 2b 2nd mounting facility thread class, 2a 1st mounting facility thread class, 4.125 inches nominal overall height

Characteristics

Below are the official specifications and performance details for this part, including technical data, material composition, and compliance information.

Thread Class
2a 1st mounting facility
Thread Class
2b 2nd mounting facility
Hazardous Locations/Environmental Protection
explosion proof
Overall Length
4.000 inches nominal
Overall Height
4.125 inches nominal
First Flat Length
0.875 inches nominal single actuator
Shaft Diameter
0.375 inches nominal single actuator
Individual Section Quantity
4
Knob Manufacturer Code
82121
Nonturn Device Type
slotted bushing at 3:00 o'clock
Longest Horizontal Distance Between Mounting Centers
2.281 inches nominal 2nd mounting facility
Longest Vertical Distance Between Mounting Centers
2.281 inches nominal 2nd mounting facility
Switch Contact Basic Design
nonpile-up symmetrical
Pole Quantity
1 4th section front
Pole Quantity
1 2nd section front
Pole Quantity
1 3rd section front
Throw Quantity
2 2nd section rear
Throw Quantity
2 3rd section rear
Throw Quantity
2 4th section rear
Mounting Method
bracket and threaded hole 2nd mounting facility
Mounting Method
threaded bushing w/panel seal 1st mounting facility
Features Provided
actuator knob
Thread Quantity Per Inch
20 2nd mounting facility
Nominal Thread Size
0.250 inches 2nd mounting facility
Nominal Thread Size
0.375 inches 1st mounting facility
Contact Voltage Rating In Volts
250.0 dc at sea level
Contact Voltage Rating In Volts
500.0 ac at sea level
Switch Actuator Momentary Position
clockwise single actuator
Mounting Facility Pattern
four position rectangular 2nd mounting facility
Switch Actuator Indexing Position Quantity
2 single actuator
Shaft Type
round, flatted, threaded hole single actuator
Terminal Type
tab w/screw
Contact Switching Action
breaks before makes 2nd section rear
Contact Switching Action
breaks before makes 3rd section rear
Contact Switching Action
breaks before makes 4th section rear
Switch Actuator Positioning Increment
90.0 degrees single actuator
Detent Rotational Torque Range
+0.500 to 9.000 inch-pounds single actuator
Switch Actuator Stop Device Type
fixed stop single actuator
Contact Load Current Rating
30.0 amperes resistive load ac at sea level
Contact Load Current Rating
30.0 amperes resistive load dc at sea level
Special Features
first section is blank
Style Designator
tap, circuit selector
Thread Series Designator
unc 2nd mounting facility
Thread Series Designator
unef 1st mounting facility

Related Parts & Specifications

This NSN includes a range of related parts designed for specific operational needs. Review each item below to find in-depth specifications, functional details, and guidance for correct application and replacement.

Part Number Name
C31055 Rotary Switch

Classification Data

Detailed NSN information including identification codes, classification data, and key indicators used for cataloging, logistics, and supply management.

Type of Item Identification
4 - Partial descriptive item identification (type 1 concept)
Demilitarization
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Criticality
X - The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Federal Item Identification Guide
A052B0
Precious Metals Indicator
U - Precious metal content is unknown
Pseudo Item Name Code
0002134
Hazardous Material Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Schedule B Code
8536509025

Freight Information

Comprehensive freight classifications, shipping codes, and handling specifications for domestic and international transport compliance.

Major Organizational Entity
TX
National Motor Freight Classification Item Number
061360
National Motor Freight Classification Sub-Item Number
X
Uniform Freight Classification Item Number
34430
National Motor Freight Class Rating
M - 85.0
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
Type of Cargo
Z - No special type of cargo code applicable
Special Hand
9 - Other or no special handling required (sh)
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Air Commodity
HZ -
National Motor Freight Description
coils/yokes focus/deflection tv

FAQs

Get insights on installation procedures, operating conditions, care instructions, industry regulations, and common issues. FAQs below provide key information for 5930-00-899-9023

What is the FSCG of the NSN 5930-00-899-9023?
The FSCG of the NSN 5930-00-899-9023 is 5930
Does the NSN 5930-00-899-9023 have a Schedule B code assigned?
Yes, the Schedule B code is 8536509025
Does NSN 5930-00-899-9023 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-00-899-9023 contain precious materials?
Precious metal content is unknown
Does NSN 5930-00-899-9023 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-00-899-9023 was assigned to the Federal Catalog?
It was assigned 59 years ago, on Fri, Feb 3, 1967

Need Consumables?

Running low on essential supplies? Explore our extensive catalog of high-quality consumables designed to keep your operations on track.

Electrical Wires

Recommended for You

Discover a selection of other high-demand NSN components from our catalog. These featured parts are frequently sourced by procurement teams across defense, aerospace, and industrial sectors.

Price & Availability

Fill out the form to get accurate pricing, lead time, and stock details from our NSN specialists:

FREE

Aviation Suppliers Association Member AS9120-ISO9001 Certification

Popular Parts

Browse our top-performing parts, selected based on customer demand and procurement frequency. All listings include up-to-date specs, availability, and condition:

AN/MSQ-T43(V)
5840-01-137-5984
Radar Set
AN/MSQ-T43(V)1
5840-01-209-9146
Radar Set
AN/MSQ-T43(V)2
5840-01-209-9145
Radar Set
AN/MSQ-T43(V)3
5840-01-137-5984
Radar Set
AN/MSQ-T43(V)4
5840-01-209-9144
Radar Set
AN/MSR-T4
5840-01-142-6672
Radar Receiving Set
AN/MSS-3
6230-00-933-7737
Searchlight
AN/MST-T1
5840-01-046-7622
Radar Set
AN/MST-T1A
5840-01-105-4656
Radar Set
AN/MSW-22
5895-01-505-9933
Data Analysis Central
AN/MSW-23
5895-01-526-8477
Data Analysis Central
AN/MSW-24
5895-01-549-1475
Data Analysis Central
AN/MSW-24B(V)2
5895-01-603-3591
Data Analysis Central
AN/MSW-4
1440-00-586-5024
Guided M Launching Control Group
AN/MVR-501
5860-01-426-4980
Laser Detecting Set